Skip to main content
Next Defence - Next-Gen AI Cyber Security Firm
Australia & New Zealand[email protected](02) 9064 2614
INSIGHT

Threat Advisory on Unexpected OT Remote Access in Healthcare and Aged Care

Verify the supplier session, establish its reach and coordinate safe containment without interrupting essential care or facilities operations.

A residential care site receives an alert about a supplier connection to a facilities service after an approved support window. The same provider maintains equipment used at several sites, and the duty manager needs to know whether the session reached an operational system or a separate monitoring application. This advisory gives teams a sequence for establishing that distinction, deciding which access to restrict and confirming the resulting service state. It concerns a representative exposure scenario. It does not attribute a particular incident to a threat actor.

Establish the service and accountable owner

Record the time, site, provider, observed identity and source of the alert. Identify the gateway or management service involved and the operational function it supports. A connection associated with a facilities vendor may reach a reporting service, a management workstation or a control environment. Find out which service owns the route and which people can authorise any change affecting it. Include the duty care or facilities owner where an action could affect environmental conditions, access to the site or another essential service.

Use the approved support record and independently established supplier contact to confirm the work. Ask who authorised the session, what work was scheduled and which customer environment it should have reached. Compare those facts with the observed session. A ticket can establish that maintenance was requested. It may not establish that a particular connection occurred within the agreed scope. Record the difference and give any uncertainty an owner and a review time.

Correlate the account, path and activity records

Obtain authorised gateway, identity and application records for the relevant time range. Establish which source can identify the account, connection, destination and result. Check the applicable time zone and whether any source is delayed or held by the supplier. Identify if the observed account is a named user, a shared role or a separate service identity. Ask the provider for customer-specific evidence through an approved route. Avoid distributing resident or operational information that is unnecessary for the decision.

Compare what the sources can establish. A gateway event may show a connection without proving that an operational setting changed. An application record may show a change without identifying the person who authorised the support session. Preserve the relevant records and state which part remains uncertain. If the application or facility cannot safely provide active evidence, use approved records and observations from the operating owner. Do not extend testing into live equipment without authorisation.

Agree proportionate containment and verify it

Have the incident lead and the responsible operating owner choose an approved action. Options could include ending one supplier session, suspending a particular grant or pausing a support route while local operation continues. Identify who can carry out each action and what evidence will show it took effect. Determine which services depend on the route and which local functions remain available. NIST's OT security guidance and ASD's OT principles give context for putting safety, reliability and operating authority into this decision.

Set a review time and document the fallback. A care provider may need to continue ordinary local operation while deferring remote support. A facility may need another authorised way to monitor the service. Confirm which conditions would require escalation or a different action. Have a separate reviewer check the resulting access state, and ask the facility or care owner to confirm that the intended work remains available. A supplier acknowledgement and an observed restriction are distinct results.

Keep ransomware preparedness in view

The June 2025 update to the joint Play ransomware advisory provides context for checking access, monitoring and recovery before an incident. It does not establish a link between an unexpected support session and Play ransomware. Where evidence suggests a wider incident, have the incident owner assess scope, preserve relevant records and coordinate approved action across affected services. Give the recovery team a separate task to confirm which copies, configurations and contacts it can actually use. Avoid treating access withdrawal as proof that every affected service or earlier action is understood.

Before restoring ordinary supplier access, establish the approved account, purpose, destination and window. Check that temporary privileges and workarounds have ended and verify the expected service with the operating owner. If a configuration change may have occurred, review the authorised baseline and determine what evidence is needed before staff rely on the result. Give unresolved activity to the incident owner and confirm when it will be reviewed. Service restoration and incident closure can require different evidence.

Make the next shift able to repeat the decision

Prepare a handover that identifies the site, service, observed session, verified restriction, work still available and next supplier update. Ask an incoming duty person to locate the approved contact and explain who can decide whether support resumes. Where a different site uses another provider or route, verify that arrangement separately. Use a fictional test after the next material change to confirm that the evidence and authority still apply. The goal is a response that protects essential operation and gives the next team a clear record of what has actually been verified.

Assess supplier remote access without touching bedside systems

A medical equipment contractor may have an active gateway session but no permission to change the connected controller. For a representative non-clinical test system, correlate the approved maintenance booking, gateway account, target address, requested command and site engineering record. Distinguish a login to the supplier portal from a configuration write to the equipment. Where logs are incomplete, preserve the uncertainty and ask the vendor for customer-specific evidence rather than declaring a device compromised.

Clinical engineering should approve any session termination that could affect alarms, building services or treatment support. Rehearse a newly authorised, time-limited support connection while denying the expired vendor identity. Confirm local staff can operate the service through the approved fallback if the remote path is unavailable. Close the exercise only after the equipment owner has checked the intended configuration and recorded any vendor evidence still outstanding.

Related perspective: The remote-access advisory correlates a supplier identity, facilities session and authorisation window; the segmentation advisory addresses unexpected connectivity between administrative and restricted services. Segmentation Exposure Advisory for Healthcare and Aged Care.

Sources and further reading

Strengthen your security with Next Defence

Next Defence can help healthcare and aged care teams review OT remote access and rehearse evidence-led containment with facilities, care and supplier owners.

Explore OT, IoT & Critical Infrastructure Security ↗

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].