A care organisation receives a report that a device used for ordinary administration communicated with a service in a more restricted environment. The service supports facilities monitoring, and the same technology supplier also maintains systems used by staff. The report warrants review. It may describe an authorised dependency, an inaccurate service map or a connection that exceeds approved scope. Establish what the records show and who owns the relevant work before changing access.
In June 2025, ASD's Australian Cyber Security Centre and its international partners updated their Play ransomware advisory. The publication gives defenders a reason to review how an incident could spread and how they would contain it. This advisory applies those questions to healthcare and aged care. It does not identify a provider, site or event as affected by Play. Local evidence determines whether an access path exists and whether it was used outside its approved purpose.
Identify the services at either end of the observation
Record the source, destination, time and evidence origin. Ask the application or infrastructure owner what the event can establish. A record showing an accepted connection says little about what information was accessed or which user authorised the activity. Preserve relevant records under the organisation's procedures. Assign an owner to each gap and set a review time.
Map the destination to a care or facilities outcome. Examples include a system used to report environmental conditions, a shared support service or a platform that carries records used by a clinical team. Identify the care, facilities and technical owners. Ask which work must continue if one connection is restricted. NIST's operational technology guidance and ASD's OT cyber security principles emphasise operating constraints such as safety and reliability. Establish those constraints with the people authorised to make site decisions.
Check the conditions that could allow activity to spread
Compare the expected boundary with approved configuration, support agreements and available event records. Look for shared service identities, remote support roles, common management platforms and integrations with separate permissions. Confirm which routes are authorised, how they are restricted and whether a provider can act across more than one environment. A shared provider name may cover several roles and support paths. Verify the actual grant rather than inferring scope from the contract title.
Consider whether an identity can reach both the ordinary and restricted services, whether another system can perform work on its behalf and whether the relevant events are visible. These are different conditions. Check for a recently changed approval or an out-of-date service map. Compare time, role and service identifiers across identity, access and application records. Look for observations that warrant escalation, such as a connection outside the agreed support window, a newly assigned role without a matching approval or a service action inconsistent with the assigned work.
Choose a safe action that the responsible owner can verify
Give the incident owner the observation, possible scope and operating effect. Identify which steps the technology team can take under existing authority and which need a care or site decision. The organisation may be able to hold one provider session, restrict a specific identity or use an approved alternative for part of the work. Set a review time and identify the evidence needed to confirm the new state. If a provider must act, agree what it will verify and how the customer can check its part of the result.
Protect local work while evidence is gathered. A facilities owner may have an approved way to observe a site function without an external support connection. A care team may need a controlled alternative to reach a record. Verify the approved fallback using a representative exercise or synthetic records. Do not apply changes to operational equipment solely because a central team received an alert. Confirm the site authority, allowed scope and operating conditions before any such decision.
Verify both the boundary and the care outcome
Ask an independent authorised person to observe the restriction through an approved environment or customer-side evidence. Check that the restricted path no longer performs the intended test action and the approved care or facilities work remains available. Where a third party owns a separate route, request customer-specific confirmation and record the limits of that evidence. Confirm the status of temporary roles and the next decision if an approved fallback is still needed.
Record what changed, what remains uncertain and which person will review it. Earlier application use may still require investigation after the boundary is restored. If the event could involve personal information, refer the available facts to the responsible privacy or incident owner. Keep records of earlier activity separate from evidence of current access. That distinction matters when the organisation decides whether work can resume and whether another assessment remains open.
Keep the result usable at the next site or shift
Ask an incoming duty person to locate the current service map, approved support path and evidence of the restriction. Have them identify which work can proceed and what would trigger another review. If a different site uses another provider or device environment, verify its relevant conditions separately. Give unresolved issues an owner and a test date. This makes the exposure review useful both for the immediate decision and for checking whether the same weakness can return after a maintenance or supplier change.
Verify the clinical device boundary before calling segmentation effective
A hospital may isolate an imaging appliance from the general office network yet retain an undocumented pathway through a vendor support host. Map the authorised flow for images, worklists and maintenance diagnostics using the clinical system owner’s actual service dependencies. In a lab using synthetic study identifiers, attempt access from an ordinary office account to the restricted maintenance route. The network and host controls should deny it while an approved radiology workflow completes successfully.
Do not deploy intrusive scanning to medical equipment without clinical engineering approval. Ask the vendor for the expected ports, access methods and software support constraints, then record the compensating boundary if direct patching is unsafe. After changes, reconcile queued images and test that the receiving system associates each study with the correct fictional patient. A firewall rule by itself cannot prove workflow integrity or absence of lateral movement.
Related perspective: The segmentation advisory asks whether administration traffic reached a restricted care service; the OT remote-access advisory investigates supplier sessions outside an approved maintenance window. Threat Advisory on Unexpected OT Remote Access in Healthcare and Aged Care.
Sources and further reading
- ASD and international partners, Play ransomware advisory, June 2025 update
- NIST SP 800-82 Rev. 3, Guide to Operational Technology Security
- ASD and international partners, Principles of Operational Technology Cyber Security
Strengthen your security with Next Defence
Next Defence can help healthcare and aged care teams assess segmentation boundaries and rehearse safe containment with their operational and technology owners.