Skip to main content
Next Defence - Next-Gen AI Cyber Security Firm
Australia & New Zealand[email protected](02) 9064 2614
INSIGHT

Resource-Sector AI Assistants: Keep Cloud Tools Outside Plant Authority

Keep engineering AI assistants away from plant authority. Test prompt injection, cloud connectors, document provenance and restricted data access.

A suspicious engineering assistant needs a business owner

An energy engineering assistant retrieves maintenance guidance containing instructions to send a plant diagram through an unapproved cloud connector. The first question is which real-world action the security control must protect. In ordinary operation, an authorised engineer reads the current procedure and prepares a maintenance proposal for independent review. The control needs to preserve that authorised journey while rejecting a request whose identity, scope or provenance is wrong. Start with the transaction or service outcome, then work backward to the accounts, devices, integrations and external partners that influence it.

Keep the assistant on the advisory side of the plant boundary

An engineering AI assistant may legitimately summarise maintenance manuals and propose troubleshooting steps, but those functions do not justify direct control of operational equipment. Document the assistant’s retrieval corpus, connected APIs, model service, user roles and permitted output destinations. A diagram, process setting or plant security procedure may be sensitive even when it is not customer personal information. Separate a read-only documentation tool from a connector capable of querying production storage, issuing maintenance requests or modifying control configurations. A user asking for a procedure should receive an answer with source provenance, not an autonomous change to a live asset. Human engineering authority must remain explicit for recommendations involving safety or service interruption, and provider agreements should cover how confidential plant material is processed and retained.

Treat retrieved instructions as untrusted data

Prompt injection occurs when text retrieved from a document or outside source tries to redirect the assistant’s behaviour. A forged instruction in a maintenance bulletin might tell the tool to upload a schematic or contact a new address. That text should be treated as content to be assessed, not as a privileged command. Record the document’s source, version and trust level, and separate tool instructions from quoted source material. Where the assistant can call external APIs, enforce destination and action restrictions independently of the model’s judgement. Test with fabricated diagrams and intentionally adversarial passages in a laboratory environment. A response that merely refuses in natural language is not enough if a connected service already made an unauthorised request in the background.

Build a grounded tool-use test with negative evidence

Prepare a synthetic maintenance bulletin containing correct technical context and one embedded instruction to send information to an unapproved cloud endpoint. Ask a test engineer a legitimate question requiring retrieval from that bulletin. The assistant should cite the approved revision, avoid elevating the injected text into an operational instruction and make no unauthorised external API call. Inspect connector logs, service-principal scopes, destination network controls and any data retained by the model provider. Repeat with a user who has narrower project permission and verify the assistant cannot retrieve restricted drawings. The most persuasive result is the denial recorded at the connector or storage API alongside an accurate, useful advisory answer. Use fictional operational material, not a real sensitive plant schematic.

A worked decision for engineering assistant

For an engineering assistant, the strongest boundary may be between a read-only manual repository and a connector that can query production cloud storage. Use a fabricated turbine maintenance bulletin with a malicious instruction embedded in a footnote. The tool should cite the correct bulletin revision without sending plant schematics to an unapproved destination. Record the exact tool identity and destination API result. A summary that claims to have followed instructions is insufficient if a downstream call succeeded. The engineering owner should approve any change to the assistant’s connected tools as if it were a modification to the maintenance information process.

Prepare an incident response that does not disable essential engineering

If an assistant appears to follow a malicious document, first determine whether an external request was attempted, accepted or merely described in generated text. Suspend the affected connector or token where possible while preserving authorised read-only access to approved documentation. Review logs for earlier similar requests and identify the affected information classes. Engineers may need a trusted manual lookup route during the investigation, especially for urgent maintenance. Do not assume a model output is evidence of a plant change without checking the authoritative control system. Conversely, do not trust the assistant’s account of its own actions when connector logs can establish what happened. Any notification or supplier escalation should follow the verified evidence and contract obligations.

Document the model's data handling in vendor terms

The assistant may send retrieved passages, user questions and tool results to a hosted model service. Before allowing plant documentation in that flow, establish the approved data classes, hosting arrangement, access controls, logging and retention commitments. A vendor’s general confidentiality statement may not answer whether prompts are retained for troubleshooting or used to improve a service. Have the information owner classify representative diagrams and manuals, then test whether forbidden material can be retrieved or exported through the assistant’s integrations. Where information must remain within an approved environment, enforce the constraint in network, identity and connector design, not only in an instruction telling the model to avoid disclosure. A successful demonstration should record the tool call, destination and access decision without exposing the sensitive plant data under test.

Govern the assistant as a changing integration

Track who approves new retrieval sources, model upgrades, plugin permissions and destinations. Reassess the trust boundary whenever a tool gains write access or a vendor changes data-handling terms. Require test fixtures for misleading documentation, cross-project retrieval and forbidden tool calls in the release process. Report outcomes that engineering can interpret: correct source retrieval, rejection of an injected instruction, absence of an unauthorised connector result and a usable human review path. A high refusal rate alone does not prove safety and may obstruct legitimate engineering work. The business goal is to improve knowledge access while keeping the authority to alter plant operations in accountable, separately controlled systems.

Plan for outdated or conflicting engineering advice

A model may retrieve an older maintenance bulletin that contradicts the current approved plant procedure. The tool should disclose its source and revision and avoid presenting an unsupported recommendation as an operational directive. Establish which document repository is authoritative and which engineer can adjudicate differences. Test a synthetic conflict by publishing two fictional bulletins with distinct revision dates and asking the assistant for a specific procedure. The answer should point to the current source and signal uncertainty where the corpus cannot resolve it. Human reviewers remain responsible for maintenance decisions, especially when equipment-specific safety rules apply. During a cyber incident, withdraw suspect documents and connectors from the assistant’s retrieval path until provenance is checked. Confidence in fluent prose is not a substitute for verified engineering instructions.

Keep testing aligned with engineering changes

New manuals, retrieval indexes and tool integrations can alter the assistant’s effective access even when the model version stays unchanged. Add a controlled check whenever a maintenance repository is reorganised or a connector receives another permission. The engineer should be able to identify the bulletin revision used in the answer and review any proposed action before it reaches a work order or field system. Record failures to retrieve the correct source separately from unauthorised data movement; both are serious, but they need different remediation. A revised assistant is ready only when its allowed advisory task remains useful and its forbidden connector path still fails.

The two results the business should ask to see

For this decision, verifiable maintenance advice without unauthorised data export should be tested through two separately recorded requests. The first demonstrates that an authorised engineer reads the current procedure and prepares a maintenance proposal for independent review. The second demonstrates a denial when text retrieved from a supplier document is treated as approval to export sensitive engineering data or alter a cloud permission. Record both outcomes, the application or gateway that enforced the rule, and the person who accepted the operational consequence. That evidence supports a narrower investment decision than an abstract request to improve cyber security across the organisation.

Sources and further reading

How Next Defence can help

Next Defence can help secure AI assistant retrieval, tool permissions and sensitive plant documentation. A scoped review should agree the authorised business action, the prohibited outcome, the evidence owner and the retest before considering a control proven.

Explore the relevant security capability

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].