Skip to main content
Next Defence - Next-Gen AI Cyber Security Firm
Australia & New Zealand[email protected](02) 9064 2614
INSIGHT

Machine Safety and Security Monitoring: Avoid an Unsafe False Positive Response

A manufacturing SOC wants to automate isolation of devices exhibiting abnormal traffic. Practical checks, containment and acceptance criteria for plant safety and cyber leads.

Security monitoring must not create a process hazard

A factory runs programmable controllers, safety systems and operator stations that must keep production within defined physical limits. A monitoring tool may flag unusual traffic or a compromised engineering laptop and recommend isolating the device immediately. In a conventional office this might be a sensible default. In an industrial environment, an unplanned isolation can sever a controller’s supervisory connection, interrupt an operator’s visibility or disrupt a coordinated shutdown. Security containment must be evaluated against the plant’s safe operating state, not only the severity of the network alert.

The first step is to understand which components perform safety functions, which perform ordinary process control and which provide monitoring or remote support. Those roles are not interchangeable. A security platform that can disable a network port may have unintended influence over operator displays or maintenance communication. Industrial engineers should identify dependencies and approved isolation points before an incident, while security analysts describe exactly what their automated response would change. A playbook that says ‘disconnect the affected device’ is incomplete if nobody knows what that device controls.

Separate signal confidence from response authority

A behavioural alert might reflect a scheduled calibration, firmware transfer, vendor diagnostic session or real unauthorised activity. Investigators should examine the source asset, protocol, time, work order and expected maintenance window before interpreting an anomaly as hostile command execution. Where telemetry is sparse, the analyst should explicitly distinguish a suspected condition from an observed malicious action. A high severity label does not substitute for evidence about the physical impact of taking the proposed defensive step.

Response authority should follow the site safety structure. A security operations centre may raise an urgent alert, preserve traffic and recommend containment, but an authorised control-room or engineering lead should approve actions that could affect production or protective systems. For a genuinely unsafe condition, established safety procedures may take precedence over a standard cybersecurity approval chain. Document who holds the decision at different hours and how the security team contacts them when communications are degraded. Joint rehearsals are more reliable than exchanging escalation charts after an alarm.

Design non-disruptive containment options

Possible responses include disabling an unnecessary remote-support session, revoking a compromised supplier credential, restricting a jump host’s upstream route or isolating a management workstation while leaving controller-to-controller traffic untouched. The appropriate option depends on plant architecture. A zone boundary that has been designed and tested for containment may be safer than unplugging a single device with undocumented shared dependencies. Maintain known-good configuration exports and a mapping of switches, firewall rules and industrial communication flows so the team can explain precisely what a rule change will interrupt.

Some protocols and legacy devices are sensitive to packet loss, active scanning or frequent session resets. Security testing should use passive observations or a representative lab where possible, with engineering approval for any active probes. Avoid using a production controller as a test target merely to prove that a security tool can block a port. Demonstrate the planned response first on a test network that reproduces the relevant dependencies, including operator visibility and expected safety interlocks.

A drill with a deliberately misleading alert

In an exercise, introduce a simulated alert that resembles unauthorised engineering software activity during a scheduled maintenance task. Give the SOC the network event but withhold the work-order context initially. The desired behaviour is to identify the asset, contact the authorised site lead and check the maintenance plan before executing a disruptive action. The team should preserve the alert details and inspect available session evidence, not silently ignore it. Then introduce a separate simulated event in which a remote-support account is used outside the approved work order and ask the same team to isolate the support pathway without disturbing local control.

Measure both sides of the outcome. Can the plant maintain safe operation while the suspicious access is stopped? Did the SOC communicate quickly enough to influence the decision? Did the control-room operator receive an intelligible account of the proposed firewall or access change? If the action is denied for safety reasons, record the residual security exposure and the next safe opportunity to remove it. A refusal to act immediately can be a correct controlled decision, but it should not become an indefinite undocumented exception.

Recovery after a security-driven interruption

If isolation inadvertently affects operations, restoring network connectivity may not restore process state. Engineers must establish whether controllers buffered commands, sensors lost continuity or operators acted using incomplete displays. Use established restart procedures and independent process checks, not simply a dashboard showing endpoints online. The security team should retain the original alert and changes made during containment, while the plant owner confirms that the resumed state meets safety requirements.

Supplier relationships complicate the recovery. A maintenance contractor may have an active work permit and a remote session when the alert occurs. Revoking that session can leave an incomplete calibration or firmware operation that should not be resumed blindly. Coordinate the change with site engineering and document whether the task must be restarted, independently inspected or formally abandoned. Temporary substitute access should be specific to the work order and expired afterward.

Governance that can be tested on a quiet day

Maintain a register of monitoring tools permitted to take autonomous action, the assets they can affect and the exact safeguards around that authority. Review changes to those permissions after new production lines, network segmentation projects and tool upgrades. Include evidence that emergency contact details and decision rights work on night shifts. Track unsafe automated blocks, alerts with unknown asset ownership and delayed engineering consultation alongside traditional detection metrics.

The successful outcome is neither ‘block everything immediately’ nor ‘never isolate OT’. It is a decision system that can contain a credible intrusion at a prepared boundary while maintaining the physical safety and service obligations of the facility. A technically correct alert that triggers an unsafe control action is not a successful security response.

Test change authority before an emergency

In a routine maintenance window, rehearse a proposed containment action that engineering approves but ultimately decides not to apply. The team should still document the expected network flows, physical impact and rollback steps. This provides a useful safety decision record without disrupting production. Next, simulate a credible compromise of a remote maintenance account while a controller remains healthy. The exercise should establish whether the team can revoke the account at the access gateway and preserve local plant control, instead of resorting immediately to a broad switch shutdown.

Alert thresholds require industrial context. A scan pattern that is suspicious in an office network might be a vendor diagnostic in an isolated test cell, while a small change to a controller programme could be high consequence even with limited network traffic. Security engineers and plant specialists should agree which behaviours matter for the installation. Changes to these detection rules need testing after new controllers, firmware updates and topology changes. A general security tool’s default severity setting should not become the site’s automatic decision about physical containment.

Where the facility uses a safety instrumented system, its protective purpose and modification governance must remain distinct from ordinary IT security controls. An incident playbook should never imply that a cyber analyst can override safety protections simply to restore telemetry or prove that a block worked. The authority and evidence required for such changes belong with appropriately qualified site personnel.

Make asset changes visible to both disciplines

An engineering change that replaces a network switch or introduces a new supervisory display can invalidate the assumptions behind a cyber response plan. Require a review of relevant isolation paths and monitoring dependencies when the plant architecture changes. That review should be proportionate and practical: identify the new traffic paths, confirm who owns them, test the effect of a blocked support session and update contact details. Security platforms should not quietly inherit permission to disrupt the newly connected assets because they reused an old address range. A site with reliable change records can make faster incident decisions because operators know what the proposed containment action will touch. The absence of that record should lower confidence in automated isolation rather than encourage a more aggressive guess.

Sources and further reading

How Next Defence supports this work

Next Defence can work with the plant safety and cyber lead to verify the specific exposure, help implement the proposed control (create passive-first detection with engineering-gated response for safety-critical assets) and document a repeatable test using controller dependency map, process state telemetry and isolation approval pathways. Engagement scope and outcomes depend on the organisation’s systems and agreed testing authority.

Explore related security capabilities

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].