A useful AI proposal still needs a safety boundary
Consider a water utility that wants an assistant to summarise maintenance records and help schedule pump inspections. The tool could save engineers time, but an unreliable summary might omit a mandatory check or attribute a reading to the wrong asset. Map the exact purpose before discussing deployment. The first role may be read-only retrieval of approved documents; it does not need to issue work orders, modify plant configuration or operate a supervisory system. Have an engineering owner define what an acceptable answer looks like, how the source revision will be verified and when a human must intervene. The NIST AI Risk Management Framework provides a useful governance vocabulary, but its use does not replace a utility-specific safety case or technical permission boundary.
Inspect the trust path behind every retrieved document
Document the path from the engineer's question to the search index, source repository, model provider, application connector and user interface. Mark where vendor manuals, sensor exports or external updates enter the process. An outdated maintenance procedure can be incorrect without being malicious; an injected instruction inside it might try to redirect the assistant toward unrelated credentials or operational data. Treat such content as evidence to interpret, not as permission to call another system. Test a fabricated vendor document with a request to export an engineering file to an external address. The connector must deny the call independently of any model-generated refusal. Keep production secrets and genuine control instructions out of the test. Record the source document, attempted action and enforceable application decision.
Keep the model out of the actuation pathway
A recommendation about operational equipment should not become a command simply because the chat response sounds confident. Identify whether any proposed integration can create a maintenance ticket, update an asset field, alter a remote access grant or request a configuration deployment. Separate a drafted recommendation from a submitted work order and from an approved physical action. The authoritative system must verify the user's identity, permitted operation and independent approval. Where a write-enabled tool is necessary, use narrowly scoped service permissions and supervised test transactions. Do not give the assistant a shared administrator credential that can reach an entire site. Restrict higher-consequence actions until engineering, operations and security have demonstrated both expected success and reliable denial.
Test accuracy against controlled engineering sources
Prepare an evaluation set with a current approved procedure, an obsolete version, a deliberately ambiguous asset label and a request with no authoritative answer. Ask the assistant to identify the right revision and say when evidence is insufficient. Have a second engineer assess the answer without seeing the model's reasoning, and record source accuracy, correction effort and potential operational consequence. A fast response is not a benefit if it makes the reviewer spend longer finding mistakes. Include a normal document lookup to ensure restrictions do not stop useful work. Evaluate the application against the utility's actual process, not generic benchmark scores. The pilot is successful only when users can reproduce useful, traceable results without relying on invented maintenance facts.
Prepare for supplier, cloud and network failure
If the model provider, search index or network connection fails, operators still need controlled maintenance information. Identify the approved non-AI repository and the route for obtaining current procedures during an outage. Test the assistant being disabled while the underlying document and work-order services remain available. Verify that any queued actions are stopped or reconciled and that a support engineer can retrieve logs without granting the supplier wider access. Do not make critical operational decisions depend on a conversational interface that the utility cannot control or restore. The business continuity plan should distinguish an unavailable convenience tool from a failure of the plant or safety-control systems.
Give privacy and supplier terms an operational owner
Engineering notes, customer infrastructure maps and staff identifiers can appear in AI inputs even when a project describes its data as technical. Ask the provider where prompts, uploaded documents and tool traces are stored, who can access them and what contractual deletion and incident-notification terms apply. Define data classes approved for the pilot, and use synthetic examples wherever possible. Identify which business owner can permit a new data source or tool connection and who can revoke it. The presence of a supplier security certification does not prove that the utility's connector permissions are safe. Audit the effective scope and the result of a direct denied access test instead.
Re-evaluate at every capability change
Models and integrations can change without a visible redesign of the user interface. Require a fresh check when a supplier adds a tool, changes data retention or enables actions beyond search. Keep a register of model, connector, source repository, credential, risk owner and tested failure scenarios. A new capability to send notifications or alter a work order materially changes the safety case. Retest the prompt-injection example, the ambiguous source question and the off switch after significant updates. Record the decision to expand or decline a feature based on evidence. Utilities should be able to explain what the AI can influence and which controls remain independent of it.
Measure benefit without overstating resilience
Track useful outcomes such as a reduction in time to locate an approved document, fewer missed source revisions and a demonstrable denial of unauthorised tool calls. Record the number of uncertain answers and the burden placed on engineers to review them. Do not count model responses as completed operational work. Give leadership a short account of the business task improved, current permission scope, unresolved data-handling issues, safe fallback and next review. If a conventional search service delivers similar results with fewer access risks, that is a legitimate alternative. A sound AI governance decision should preserve safety, accountability and essential service continuity even if the model is wrong or unavailable.
A change request the assistant must not complete
Use a fictional maintenance planning scenario in which an engineer asks the assistant to locate the approved inspection interval for Pump 4. The assistant retrieves an obsolete vendor note that also contains an instruction to change a maintenance threshold in the asset system. The legitimate outcome is to identify the current controlled document and explain the uncertainty; the model must not execute a threshold change. Capture the attempted API operation and confirm the destination service rejects it for the read-only identity. Then submit the proper authorised work order through the independent maintenance application and verify it succeeds after engineering approval. This paired test distinguishes useful information retrieval from delegated operational authority. A generic assertion that humans remain in the loop is insufficient if the connector can change settings without checking an enforceable approval.
How to decide whether the pilot should grow
Prepare an acceptance sheet listing the allowed data sources, supported task, expected output, source accuracy, forbidden tools, retention rules and fallback. Require a successful controlled document search, a denied unauthorised write attempt and recovery from a disconnected AI service. Record whether the operator took longer to correct generated text than to use the original procedure. A pilot that repeatedly creates ambiguity or requires broad service credentials may have negative value even when its demonstrations are visually impressive. Assign the decision to expand to the operational sponsor and security owner, with engineering able to veto unsafe changes. The next pilot phase should extend only one permission or data source at a time, accompanied by another boundary test and a defined reversal procedure.
Keep a record of why the tool was approved
The operating sponsor should publish the narrow purpose of the AI tool, the approved sources, the prohibited actions and the safety review used to support the pilot. When staff encounter an unexpected answer, they need an accessible route to report it and return to the authoritative procedure. Security should investigate whether the issue involves incorrect source data, a prompt injection or excessive integration permission; these require different corrections. Retest the specific failure rather than assuming a generic model update resolves it. Document successful authorised use alongside denied actions to show the tool remains useful within its boundaries.
Separate an informative maintenance suggestion from plant authority
Give the proposed utility assistant an obsolete pump-maintenance bulletin and a newer approved procedure with a similar name. It should cite the controlling revision, disclose uncertainty where asset identifiers conflict, and refuse to infer a safety clearance from an incomplete record. An engineer should be able to view the source directly without following a machine-generated instruction through an operational system. This exercise measures whether the model helps find evidence, not whether its prose sounds convincing.
Add a simulated prompt embedded in a supplier report instructing the assistant to alter the maintenance priority. The expected outcome is no work-order release, no privileged connector call and a visible report of the attempted instruction. If the cloud service fails mid-shift, staff must still retrieve the current approved procedure through an independent route. A tool that preserves that boundary may be suitable for a narrow knowledge pilot, but it is not equivalent to an authorised controller or a replacement for engineering sign-off.
Sources and further reading
- NIST, AI Risk Management Framework 1.0
- ASD and partners, Engaging with artificial intelligence
- ASD and partners, Principles of operational technology cyber security
Strengthen your security with Next Defence
Next Defence helps utilities assess AI integrations, enforce tool boundaries and run operationally safe governance and validation exercises.