A utility wants staff to find approved maintenance information more quickly. A supplier offers an AI search tool that can summarise procedures and suggest a next step. The workforce may save time, but the proposed integration could also give the tool access to restricted records or lead operators to rely on an unverified answer. The decision should start with the task and the consequence of an error. Introduce the tool in stages, give each stage a named owner and retain an independently usable operating process. The example here is a support tool for people, with operational control remaining with the authorised teams and systems.
Choose a use case with an observable benefit and limited authority
Pick a task such as finding a current procedure, identifying the owner of a maintenance record or drafting an internal support request. Ask the operating owner which work it supports and what happens if the tool is unavailable or wrong. Compare the proposed workflow with the existing one. A useful pilot might reduce the time needed to locate the right document while leaving the approval and execution process unchanged. A task that would create a new dependency for essential work requires a different decision about service design and recovery.
Map what the tool will read, store and send. Identify source collections, identity services, supplier components and any connections to other applications. Confirm how the tool determines what each user can see. Ask what authority it has when returning a result or creating a draft. Give the operating, information and technical owners separate responsibilities. The operating owner sets the permitted role in essential work. The information owner decides which records can be used. The technical owner verifies the access and integration boundaries. Agree who can stop the pilot and how staff will continue approved work afterwards.
Ask the supplier to prove the controls in the proposed configuration
The joint secure AI development guidance published by ASD and its partners describes security considerations across design, development, deployment and operation. Use it to ask for evidence tied to the product and environment under review. Ask which data the supplier can access, whether it retains inputs or results and how customer access settings are enforced. Identify what changes when the provider upgrades a model or introduces a feature. Record which decisions remain with the utility and which need supplier action. Require evidence that a new connection or source can be withdrawn.
Bring a fictional document and two approved test roles to the demonstration. Show that a role entitled to a procedure can find the current record and that another role cannot retrieve its restricted content. Ask the supplier and information owner to explain where the entitlement was enforced. Verify how the result identifies the original approved document and how a retired version is removed. If a claim cannot be tested without access to production information, agree a representative environment or record the limitation. A procurement decision should make the gap visible rather than treating a product description as assurance.
Run a read-only pilot alongside the ordinary process
Start with an approved collection of non-sensitive or fictional records and a small group of representative users. Use a defined window and record the baseline time and steps for the ordinary task. Ask staff to compare results with the source rather than treating a plausible summary as an instruction. Give them a way to report a missing, stale or misleading answer. Identify the owner who will assess each report and record what evidence would justify changing the tool, its content or its permitted use.
Include a controlled test of a misleading instruction inside a fictional document. The expected behaviour is that the document remains information for the authorised task and cannot extend the tool’s permissions or issue a command to another service. Use the approved test environment and observe only the agreed outcome. Have the information owner verify whether the relevant records stay within their intended boundary. If the tool produces an unsafe recommendation, ask the operating owner how staff would recognise that the approved procedure still controls their work. This helps the pilot address both technical behaviour and human use.
Verify continuity before widening the rollout
Simulate unavailability during an ordinary shift. Ask the duty team to find the approved material and complete the representative task through the established procedure. Confirm where current records remain available and who can decide whether to suspend the tool or continue the pilot with a smaller scope. Give an incoming shift the handover and ask them to identify which work is affected and which process to use. If the fallback depends on a service that would be unavailable in the same incident, assign an owner to establish an independent route and test it.
ASD’s operational technology principles put safety and knowledge of the business context at the centre of security decisions. Apply that thinking when the tool may influence maintenance or an essential service. A pilot that helps a person find information may have modest operating consequences. A later design that starts a workflow or controls a physical action changes the authority and the evidence required. Keep the stages distinct. Ask the responsible operating authority to review any material change before it is used. Test ordinary work as well as the new capability so a positive pilot result does not hide a loss of resilience.
Put a clear decision gate between pilot and expansion
Give the sponsor a brief record of the outcome, including the service, users, results, incidents and limits. Compare the observed benefit with the evidence about data access, provenance and recovery. Set conditions for expansion. The owners should be able to show that restricted records remained within their intended boundary, the ordinary process worked when the tool was unavailable and staff understood who can approve real work. A gap may justify another limited pilot, a supplier change or a decision to keep the tool away from a particular workflow.
Assign review triggers after approval. Reassess access when the supplier adds a connection, when new data is indexed or when the utility proposes a different use. Give the service owner responsibility for the operating outcome, the information owner responsibility for content and the technical owner responsibility for verification. Agree how results are retained and who can stop the service outside office hours. At the next review, repeat an authorised task, an excluded role and the fallback. Record where the conditions differ. The utility should be able to show that the tool supports work and that essential services can still operate within their established authority when the tool changes or stops.
Record the evidence needed to stop or change the service
Before the pilot ends, write down the test that would show a suspension worked. For a document search tool, the information owner might remove an approved test collection, have the technical owner confirm that the tool no longer returns it and ask an operator to locate the same document through the ordinary controlled source. Check whether cached results or another supplier component need a separate action. Record the observed state and the person who accepted it. Give the duty team a simple way to recognise when staff should return to the normal procedure and who can authorise a later restart.
Keep essential utility decisions independent of the AI pilot
Choose one low-consequence question, such as finding an approved maintenance procedure for a non-critical asset. Compare the assistant’s response with the controlled document repository, checking revision, site applicability and whether the text omits a mandatory safety step. In the pilot, the AI may locate and summarise an instruction, but switching equipment, issuing field work and approving a maintenance permit must remain within the existing human-controlled system. An attractive answer with no traceable source should fail the acceptance test even if it happens to be correct.
Ask the crew to repeat the same task when connectivity or the AI service is unavailable. Record the time required to locate the authoritative document manually and whether the service desk still receives the request. This becomes the continuity baseline against which any efficiency claims are assessed. The operations sponsor should cap the first rollout to named groups and documents, track unsuitable suggestions separately from ordinary search failures, and require explicit approval before allowing new data repositories or actions. Supplier model changes should trigger a representative repeat test because a previous prompt result is not proof of continuing control.
Sources and further reading
- ASD and partners, Guidelines for Secure AI System Development
- ASD and partners, Principles of Operational Technology Cyber Security
Strengthen your security with Next Defence
Next Defence can help critical infrastructure and utilities teams assess AI use cases, define supplier evidence and test a rollout before it affects essential work.