Find the technology that sits outside the IT inventory
A modern legal practice may depend on access-control panels, smart meeting rooms, multifunction printers, CCTV platforms and building services maintained by third parties. Some connect to a landlord network, others share corporate Wi-Fi, and a few use unattended remote support. They rarely appear in the matter-management system's security review. Start with a site walkthrough involving facilities, IT and the practice manager. Record the purpose, connection, software support owner and access method for each device. A meeting display is not a client database, but its management service may provide a route toward a directory or shared administrative workstation. The risk decision depends on the actual connectivity and business dependency rather than the word 'IoT' on a product brochure.
Separate building maintenance from confidential records
Trace the network path from a supplier workstation or building controller to file shares, identity services and matter-management applications. Identify which connections support a legitimate facility function and which should be denied. In a permitted, non-disruptive test, use a representative device or network configuration to confirm that an unauthorised route to a synthetic legal document repository fails. Check that an authorised maintenance action can still occur. Avoid intrusive active scanning against fragile control devices or systems that affect emergency egress. A firewall diagram alone cannot establish an effective boundary if the supplier's remote support jump host has broad access to ordinary staff systems. Record actual decisions and the system enforcing them.
Protect the remote maintenance identities
A door or HVAC supplier may maintain credentials long after a building renovation. Determine which named engineer or service account can access each controller and whether permission expires after approved work. Shared permanent passwords make it difficult to attribute changes, while vendor-installed remote software may provide an unmonitored alternative path. Use an approved gateway or supervised access process where appropriate and retain a maintenance record showing who connected and what was changed. Test that the account of a former supplier is denied without interrupting essential building functions. Where equipment lacks modern authentication, document a compensating network restriction and review date. Security ownership needs to survive landlord, supplier and office relocations.
Include physical safety in every containment choice
A suspicious control-system connection should be investigated without automatically disconnecting a device that supports safe access to premises. Ask facilities to define which functions require continued operation, what a safe local or manual fallback looks like and who can approve a restricted management connection. Use a scenario in which a building vendor account shows unexpected activity while the practice has an important court filing deadline. The response should preserve relevant network and vendor logs, choose a narrow restriction and ensure staff can enter, leave and use essential office facilities. Security responders need a business and safety owner for consequential changes; the correct action will depend on evidence rather than a universal rule to unplug every suspicious device.
Treat printers and conferencing equipment as data paths
Smart printers can store scan history, email destinations and authentication settings. Meeting systems may handle calendar invitations and sensitive discussions. Examine retention and access settings proportionately, especially during device return, replacement or external maintenance. Verify that the support account can administer the equipment without browsing unrelated matter documents or email accounts. Use synthetic data to test scanning and printing workflows after a policy change. A policy that breaks court filing or client communication may lead staff to create unsafe bypasses. The right design includes both a secure approved function and a documented disposal or reset process when the device is replaced.
Write vendor responsibilities into facilities agreements
Office services often cross a lease, managed IT contract and specialist maintenance agreement. Identify who holds administrator credentials, who patches firmware, who approves remote access and who preserves logs after an incident. Ask what evidence the landlord or vendor can provide if the practice suspects a connected-device problem. Include an emergency contact and a method for restricting one supplier without removing unrelated services. A generic statement that a landlord owns the equipment does not establish that its connection to the firm's network is secure. Translate the trust boundary into an operating agreement with identifiable decisions and practical tests.
Exercise a coordinated office incident
A controlled tabletop might begin with an unexplained building-controller login, a vendor reporting an account issue and a printer management server attempting an unusual connection. Security gathers the source and destination evidence; facilities confirms safe operating conditions; a practice partner decides how client work can continue. Participants must identify a permitted maintenance action and an unauthorised access request that should be blocked. Keep client confidentiality protected while documenting the investigation. If the evidence cannot establish whether an unauthorised session reached a sensitive system, record that uncertainty and the additional telemetry needed. The outcome should be a clear authorised restriction and restoration process rather than an unsupported declaration of compromise.
Review every connected office change as a trust change
New collaboration suites, relocated floors and outsourced building support can all alter the network and identity boundary. Build a short review into equipment installation, lease renewal and supplier offboarding. Confirm that the maintenance identity is scoped, external connections are understood and the office can continue essential functions under a controlled restriction. Report critical unowned devices and overprivileged supplier paths to the relevant decision-maker. Next Defence-style security assurance is most useful when it protects both client confidentiality and the operational services on which the practice depends. Recheck the tested boundary after material changes instead of treating a one-time segmentation diagram as permanent proof.
A building support session with too much authority
A law practice commissions a facilities supplier to diagnose a smart meeting-room controller. Its technician uses an unattended remote tool that unexpectedly allows a connection toward a corporate file server. The technician may have no intent to misuse it, but the shared route represents an unnecessary trust path. Confirm which gateway or workstation permits the connection and who owns its policy. In a representative test, show the supplier can reach its assigned controller but cannot request a document from a fabricated client matter. Record the attempt and the actual enforcement decision. The change must not compromise fire alarm, door access or other safety-relevant building functions; facilities approves the testing approach. The finding belongs to a joint practice, landlord and supplier improvement plan, not merely a request to replace one meeting-room device.
Define closure evidence before touching the network
A secure facilities improvement should state the intended permitted maintenance traffic, the unrelated access to block, the identity authorised for testing and the sign-off needed from facilities and the practice. Capture baseline configuration and log records before implementing a change. Afterward, demonstrate an allowed diagnostic connection and a denied corporate document request. Ask the supplier to confirm that its ordinary support function works and that stale credentials from earlier projects are removed. Document any system that cannot support detailed audit logging and what compensating evidence is available at the management gateway. Repeat the test when the office changes landlord, moves floors or installs a new collaboration suite. The outcome is a practical, supportable boundary that protects sensitive legal work without creating unsafe or costly building disruptions.
A practical order for office remediation
Begin with remotely accessible building management routes and any device connection that can reach a confidential file service. Confirm ownership and safe operating constraints before changing network rules. Next, remove stale vendor identities and improve session visibility. Finally, review connected printers and collaboration equipment for retained information and inappropriate cloud sharing. Re-test an approved supplier maintenance action and a denied matter access attempt after each significant change. Keep unresolved equipment limitations in an explicit exception register with a facilities owner and review date. This turns a mixed property and IT problem into controlled, accountable improvements.
Building access must not become document access
At a legal office, a facilities contractor needs to reset a meeting-room controller during a client conference. The maintenance session should reach only the device-management plane, not the document management system or print archive. Test with a simulated contractor account and a fictional matter, then verify that the permitted control action succeeds while an attempted file retrieval is denied and logged.
Include the landlord's building network and a printer that stores temporary scans. Determine which organisation can terminate a persistent vendor tunnel, who may approve an emergency safety intervention and where session evidence resides. A response plan should not assume that disconnecting a door controller is a harmless containment option. Facilities and confidentiality owners need a shared, documented decision before a live change.
Scope distinction: This connected-office review starts with an inventory of third-party-managed facilities devices and the boundaries between landlord, practice and supplier networks. The earlier office-move scenario focuses on coordinating network changes without interrupting visitor access and client work. Companion article: Secure Connected Building Systems Without Disrupting Client Work.
Sources and further reading
- ASD and partners, Principles of operational technology cyber security
- NIST, Cybersecurity Framework 2.0
- ASD, Essential Eight maturity model (November 2023)
Strengthen your security with Next Defence
Next Defence helps professional firms assess connected-device exposure, secure vendor maintenance access and protect confidential systems with proportionate operational controls.