Which OT Credentials Should Utility Leaders Address First?

Prioritise operational credentials by the consequences of misuse, the ability to change them safely and the evidence available during recovery.

A utility board is asked to fund stronger management of cryptographic keys and operational credentials. Some devices have long maintenance intervals, some integrations are operated by suppliers and several sites depend on local operation when central connectivity is unavailable. The choice is about more than a new credential platform. Leaders need to identify which authority can affect essential services, what a change could interrupt and what evidence will show the risk has been reduced. The priorities should reflect the utility’s architecture and operating responsibilities as they stood in August 2025.

Start with the authority and the essential service

Choose a few representative services and identify which credentials can affect them. A certificate may establish the identity of a service, a signing key may support software trust and an application credential may allow a vendor integration to exchange data. A support account may give a person a separate capability. Record the issuing or managing system, authorised purpose, operational owner, known consumers and evidence that shows the current state. Use identifiers or approved references in the inventory. Keep sensitive values in their authorised systems.

Ask which effects would matter if the authority were misused, lost or unexpectedly withdrawn. One credential may support a low-impact reporting flow. Another may be needed to validate an approved update, maintain an alarm route or restore a service after an outage. Give the operating team a way to explain what can continue locally and when a change needs site approval. NIST’s OT security guide and ASD’s October 2024 OT principles describe the importance of safety, reliability and operating knowledge. Those concerns should inform the order and timing of investment decisions.

Compare consequence with the ability to intervene

Use a simple comparison. Start with the possible effect on the service, then assess whether the utility knows who can withdraw, replace or verify the authority. An identity that can change several sites may deserve priority if it is difficult to revoke independently. A narrowly scoped credential used by one disconnected device may need a replacement plan because an update cannot be verified during ordinary work. Keep risk and implementation effort visible separately. A hard-to-change credential does not become low priority because the work is inconvenient.

Give each priority a decision owner and a test. A group might choose to reduce the number of sites reachable by a provider role before replacing a low-impact credential. Another might prioritise recovery evidence for a service whose trust material is bound to ageing equipment. Ask what improvement can be verified under approved conditions and what must wait for a site window. If the utility cannot identify an owner or consumer, fund the inventory and operating evidence needed to make a responsible change. A count of unknown entries is useful when leaders can see which services those entries affect.

Decide where central controls help and where site evidence is essential

Review which activities can be governed centrally and which require a local observation. A central service can hold records about a credential or grant, while the site may be the only party that can confirm how a device behaves after a change. Identify who can verify the actual result. If the supplier operates part of the process, agree what customer-specific evidence it will provide and whether the utility can observe the outcome independently. Build that requirement into a service agreement or procurement decision. ASD’s January 2025 Secure by Demand guidance gives buyers a basis for asking about product ownership, authentication, logging and configuration management.

Consider an interruption of central access. Ask how local staff will operate safely and obtain an approved service decision if the ordinary platform is unavailable. A centralised model can improve consistency and still create a recovery dependency that needs to be tested. Require a representative exercise of the approved fallback. Check that it preserves the intended authority and evidence rather than relying on an undocumented emergency route. Give the duty owner a verified contact and a review time if it must use a different operating arrangement.

Verify a transition without putting the plant at risk

Select a representative approved environment and define the intended state before any demonstration. Identify which service uses the replacement, which former authority must end and what evidence will confirm each outcome. Ask the operating owner to verify a representative task and the technical owner to confirm the access state. Include one delayed or offline consumer if it reflects the utility’s estate. A successful test on a connected device may not establish that a remote site or spare system can use the same change. Record scope and conditions explicitly.

Plan recovery as a separate decision. A configuration or image restored after an incident could depend on trust material that has changed. Ask which operating version, settings and access are required to restore the service and which older material remains necessary for a legitimate purpose, such as verifying a historical record. Have the authorised owner determine how it will be protected. Keep the recovery plan from reintroducing an obsolete access grant. Use approved evidence and site procedures for all tests, and involve the people responsible for safety where an action could affect live operation.

Bring leadership evidence that shows the investment worked

Report the scope of essential services reviewed, proportion of high-impact credentials with a known owner and tested replacement route, and time to verify withdrawal under representative conditions. Identify which sites or suppliers were outside the test. Distinguish an inventory entry, a tested technical result and an accepted operating outcome. Give unresolved dependencies a named owner and review date. Ask the board or executive to choose which gap to fund, which service boundary to maintain or which provider commitment to change.

Use a second scenario to test a different condition before expanding the conclusion. A vendor-supported connection may have a separate approval route. A remote facility may have a longer interval between opportunities to change equipment. Ask the site owner to identify the records and fallback it can actually use. The utility should be able to explain how the programme changes the risk to essential work, which authority can intervene and what evidence supports the claim. That is a stronger result than simply reporting that a large number of credentials have been moved into a new system.

Keep the comparison in the next budget review. Show which services now have a verified route to continue, which uncertainties remain and the cost of resolving the most consequential gap.

Separate a temporary operating exception from the target design

Give leaders a representative case in which an older device cannot support the intended replacement until a site maintenance window. Ask the operating owner to identify the service consequence and the technical owner to describe which controls remain in effect. A temporary arrangement needs a stated purpose, expiry, approval and observable outcome. Check that the duty person can find the record without the project team. The board can then compare an interim condition with the cost and timing of its permanent correction. If the exception relies on a supplier to act, give the contract owner a specific evidence request and schedule the next verification before the temporary arrangement expires. Retest the decision at a site whose maintenance arrangements differ.

Schedule that decision alongside the next approved maintenance review.

Rank utility OT credentials by consequence and feasible rotation

Inventory the identities and secrets used by engineering workstations, remote maintenance gateways, historian interfaces and controller-support tools. Distinguish interactive named accounts from embedded shared passwords, certificates and long-lived integration credentials. The priority is not necessarily the oldest secret: a credential that can reach several substations or change a protection setting may warrant earlier isolation, while a tightly constrained service credential with no safe rotation path needs a staged plan. Link each credential to its affected asset, recovery owner, supplier dependency and the work that would stop if it failed.

Prove the intended change on an offline replica or within a formally approved maintenance window. Verify that the old credential is rejected and the new one supports the permitted diagnostic without disrupting control, alarm delivery or local fallback. If immediate revocation would create an unacceptable operating risk, document a temporary route restriction, enhanced monitoring and an expiry agreed by the engineering authority. Report progress to leadership as reduced privilege and tested recoverability, not a percentage of passwords reset. A second site using a different gateway arrangement should be sampled before applying the same rotation plan across the fleet.

Sources and further reading

Strengthen your security with Next Defence

Next Defence can help utilities and critical infrastructure teams map OT credential dependencies and turn them into practical investment, continuity and assurance decisions.

Explore OT, IoT & Critical Infrastructure Security ↗

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].