A utility receives a provider notice about an unexpected administrative event. The security team can see a sign-in at a central service, but the event feed for the affected site stopped reporting before the activity. Operations needs to know whether staff can continue their work and which evidence will support that decision. A logging gap limits the team's ability to verify activity. By itself, it establishes neither an intrusion nor that the service was unaffected. This advisory is a defensive checklist for an illustrative situation, with changes subject to the organisation's operating and safety approvals.
Find the affected service and the event the team needs
Record the asset or provider reference, site, time and observation. Ask the operating owner which business process the affected service supports and what would happen if it were restricted. Identify which decision depends on the missing event. The team might need to distinguish an approved maintenance session from unexpected access, verify a change to an identity or confirm whether a service continued when central monitoring lost visibility. Each question may require a different source.
Map the relevant identity, management, application and site records. Include the evidence each supplier can obtain and the people who can request it. ASD and partners' guidance on event logging prioritises collection according to exposure and consequence, including considerations for OT environments. Apply it to the utility's actual services. A system whose events are important to an operating decision may need an approved local or supplier evidence route even when direct central collection is unavailable. Do not assume that collecting more data resolves a gap in the event that matters.
Determine whether the gap is generation, collection or access
Ask the source owner whether the expected event is created and retained. Determine whether the central service receives it, whether it is delayed and whether the reviewer is authorised to see it. Record the last verified observation and the time basis for comparing records. An inactive dashboard can result from a collection interruption or a loss of access to the feed. It does not establish that the underlying service stopped or that activity ceased. Use a known authorised event or an approved synthetic observation to check the relevant path.
Look for independently held evidence. A site may have an approved change record, a provider may hold a management event and an application owner may be able to confirm the resulting state. Record what each source establishes. A maintenance ticket shows what was authorised. It does not necessarily show who acted or what changed. Give every unresolved question an owner and a review time. Preserve the records under approved handling procedures and avoid distributing sensitive site configuration or identity information more widely than needed.
Decide what can be restricted without affecting safe operation
If the available evidence supports an immediate restriction, identify the person who can approve it and the service owner who can assess the effect. A limited supplier role or administrative path may be reviewed separately from the operating service. Use an approved action and have another authorised person verify the resulting state. Where a change could affect operational equipment or safety-related work, follow the site authority and the agreed operating process. ASD's OT principles and NIST's OT guide treat safety and continuity as central considerations.
Agree what work can continue under the evidence available. A local service may remain usable while the team delays an unrelated remote support task. Give any approved fallback a scope and review time. If the concern involves an identity or key management service, confirm who can verify the relevant administrative activity without requesting or copying secret values. Keep the decision about ordinary operation separate from the investigation of earlier activity. Ask the incoming owner to identify which fact could justify changing the restriction.
Verify that useful evidence is available again
Once collection or access has been restored, use an approved test event and check that the intended source, time, identity and service can be identified. Have the operating owner match it to a representative authorised action. Check whether a separate provider or disconnected site retains evidence for the missing period. Explain which facts remain unavailable and what that means for the incident decision. Restoring an event feed does not reconstruct every event that occurred while it was unavailable.
Record the affected service, last verified event, action taken, operating status and next review. Test the handover with a different duty person and a representative synthetic event. If a source can fail without anyone recognising the gap, give detection of that failure its own owner and acceptance test. The operating team should be able to tell whether it lacks visibility, which work it can still approve and what observation will allow the next decision.
Record the evidence route that remains available if central monitoring or the normal provider portal is unavailable.
Demonstrate an alert reaches the right utility operator
Select a harmless test event from an approved utility historian or remote access gateway, not from a live controller. Identify the path from the source device to the log collector, detection rule, analyst queue and site control room. Compare source timestamps and asset identifiers at each stage. An alert in a central dashboard is not useful if the duty operator cannot link the event to the affected feeder, pump or authorised maintenance session. Treat missing logs as a distinct detection failure; do not infer malicious activity from collection gaps alone.
Rehearse a loss of the monitoring connection while the operational process continues. The site owner should specify the local indicators and contact route available without cloud analytics. Verify who may request an access restriction, who must approve changes that could interrupt essential service and when the temporary restriction is reviewed. Capture the operator’s acknowledgement and the effect on the approved maintenance workflow as part of the evidence, not merely the alert count.
Sources and further reading
- ASD and partners, Best Practices for Event Logging and Threat Detection
- ASD and partners, Principles of Operational Technology Cyber Security
- NIST, Guide to Operational Technology Security, SP 800-82 Rev. 3
Strengthen your security with Next Defence
Next Defence can help critical infrastructure operators verify logging coverage and test how their teams make decisions when an essential evidence source is unavailable.