Tabletop Exercise for an Unpatched Public Sector Internet Service

Rehearse scope, safe containment and verified patch acceptance when a public-facing service has a missed update.

A public sector agency receives a vendor notice concerning a product used in an internet-facing service. The service supports public applications, and a separate team operates its hosting. The agency's inventory lists two instances. The provider can verify the version of one and says the other was restored recently. A patch is available, but the duty manager needs to know which service is affected, what can continue and how to verify the result. This tabletop uses a fictional product, advisory and environment. It tests the agency's ability to move from a credible notice to a verified operating decision without using live services or real applicant records.

Agree the purpose and exercise scope

Select one public-facing workflow with a deadline or service consequence, such as receiving licence applications or managing a booking request. Identify the platform, service owners, hosting and application providers, and the people who can approve a change. Include one internet-facing component, one separate management or standby environment and a representative dependency. Agree what ordinary work can continue if the agency holds one path. Give the facilitator the fictional evidence and appoint an observer to record decisions and unresolved questions.

Set outcomes before starting. The team should establish affected scope, decide whether an interim restriction is appropriate, verify patch or replacement acceptance and demonstrate the public workflow. It should also recognise what evidence would justify opening a separate incident assessment. Agree the time by which a duty decision is needed, where the team will retain records and who can stop the exercise. Run all messages in the approved exercise channel. Do not simulate changes on a live system. Use facilitator-provided records or an authorised representative environment.

Prepare a dated synthetic advisory with an affected release range, relevant configuration conditions and a recommended update. Include a version record for an ordinary instance, an older standby inventory and a change ticket for a recent restoration. Add a hosted service whose provider must supply the relevant details. Prepare an approved continuity option, such as retaining a limited intake function or directing customers to an established alternative. Give each option a business owner and an expiry. The participants should need to decide which information can be verified rather than assuming the advisory identifies affected agency systems.

Inject one: a notice arrives before a public deadline

Give the service desk a fictional supplier notice and a public service reference. Ask how the recipient verifies the notice and reaches the owner of the affected service. Require the incident or change lead to identify the product, current release and configuration condition described. Ask what evidence can show that the instance is reachable through the service in scope. ASD's Essential Eight guidance provides risk-based expectations for patching relevant applications and operating systems. Use that guidance with the service, vendor and agency requirements rather than applying an assumed timetable to every asset.

Give the group one current version record and one entry that might be out of date. Ask it to classify each as confirmed affected, verified outside scope or awaiting evidence. Record the source, timestamp and person responsible for each observation. If an older instance can be restored or placed into service, give its owner a separate verification. Ask what evidence would show that another provider hosts an affected service. The observer should note whether the team distinguishes inventory presence, actual exposure and evidence of earlier activity.

Inject two: the provider cannot confirm one instance

Tell the group that the hosting provider will need more time to verify the restored instance. Ask the provider liaison to use an independently verified route and specify the customer service, relevant condition and evidence required. Ask the agency what it can observe independently and which operating decision depends on the supplier's answer. Set the next update time and give an unavailable contact to the observer. Have the duty team show how it reaches the approved alternate.

Give the agency two approved interim choices. One might limit a specific internet-facing function while leaving another approved service available. The other might use an existing public service fallback while the affected instance is assessed. Ask which option is proportionate, who can authorise it and what evidence would confirm the new state. Ask the service owner what customers or staff should be told. Record the decision and when it must be reviewed. If the provider must make part of the change, give the agency a way to verify its own part of the result.

Inject three: an update succeeds in test and a workflow fails

Give the technical team a synthetic acceptance record showing the intended version installed while one fictional submission fails in the representative environment. Ask who can decide whether the change is ready for wider use. Have the service owner identify which work can continue under the approved fallback and the technical owner explain what must be verified before proceeding. Compare the observations with the expected workflow and record which condition needs correction. A version record establishes part of the result. It cannot establish that the public workflow is usable.

Ask what would happen if the previous configuration returned an affected release or reopened an earlier access path. Have the team identify a verified alternative and who can accept any temporary limitation. Check the handling of records queued during the intervention. Give the next shift a written instruction that identifies the affected instance, restriction, operating scope and time of the next review. The observer should be able to tell which part is a technology decision and which belongs to the public service owner.

Inject four: review a separate incident concern

Give the incident lead a synthetic record of activity that predates the patch. It identifies the service and time but does not establish that the reported vulnerability was used. Ask which authorised records can support an assessment, who owns them and what must be preserved before ordinary changes continue. Use NIST's 2025 incident response profile to frame the separation between detection, response and recovery decisions. Ask which evidence would justify expanding scope or involving a supplier, and who will coordinate the decision. Do not assume the fictional patch closes the investigation.

Have a different duty person read the case without a verbal briefing. Ask them to identify what is known, which version is in service, what work can proceed and which evidence is still outstanding. Verify the contact path and the next review. If a supplier can confirm the update but not earlier activity, record that difference explicitly. Keep any privacy or notification assessment with its authorised owner. A clear handover should allow the agency to maintain an approved service while another team reviews the earlier observation.

Verify the return and agree the improvement register

Give the participants a new synthetic result in which the correct version is verified and an approved test application is accepted. Confirm which role can approve the return, whether the standby instance was checked and which work must be reconciled. Verify that temporary access and restrictions have ended or remain under a named review. Ask the service owner to accept the ordinary workflow and the technical owner to confirm the observed configuration. Record the scope of both observations. Do not claim that an untested instance or provider service has been verified.

Use the observer notes to rate scope, authority, containment, patch verification, continuity and handover as demonstrated, partly demonstrated or unverified. Give each gap a consequence, accountable owner, priority, due date and acceptance test. A stale restored instance may need an inventory or recovery check. A missed duty contact may need a tested alternate. A failed synthetic submission may need an application acceptance test. Assign a date for a repeat exercise and choose a site or provider that changes the conditions. Retain the observed evidence and compare the results rather than counting activities alone.

Recheck the service after the next recovery change

Ask the hosting owner to supply a fictional restoration record for the standby instance. Have another authorised person identify the version, confirm the expected internet-facing scope and show which evidence would prevent an old image returning to ordinary use. Include an updated service contact and a provider evidence request. If one decision depends on a central system, verify how the agency reaches the owner when that system is unavailable. Record who owns the result and when it will be exercised again. The follow-up should establish whether the change addressed the conditions that made the original patch difficult to verify.

A public test server that is no longer supposed to exist

Introduce a staging service that was retired from an agency project but still resolves through an old supplier-managed DNS record. The asset team has no active owner, yet the vulnerability scan reports a reachable interface. In the exercise, participants must first verify that the record and network address identify the same system, without attempting intrusive testing against a public endpoint. Ask procurement whether the provider has authority to change the route and have the service owner approve any temporary restriction. The facilitator then reveals an unrelated critical service sharing the supplier account; deleting the whole account would cause avoidable harm. Success is an evidence-based containment plan, a named asset custodian and a follow-up check that the obsolete public path has actually disappeared.

Test the public communication independently

Ask a communications owner to prepare a fictional service notice using only the verified operating facts. The notice should tell people which approved intake route is available and what to do if they had started a request before the change. Keep speculative causes and technical evidence in the incident record. Ask a person outside the exercise team to read the notice and choose the appropriate next step. Include an applicant who needs an accessible alternative or an existing case reference. Check that the instructions are usable without directing people to an unverified link or unofficial contact.

Give the owner a second update after the test submission succeeds. Ask when the notice should change and which approvals are required. Verify that an old notice would be withdrawn or clearly superseded. The application owner should identify any records submitted through the fallback and have the service owner verify how they will be reconciled. Give the observer a way to tell whether people can distinguish the end of the service limitation from completion of the investigation.

Assign any communication gap an owner and retest it. A message that staff understood during a briefing may not work for a person who encounters it on the public site. Ask another reviewer to act on the revised notice without help. Record which route they found and who will maintain it after a platform or supplier change.

Sources and further reading

Strengthen your security with Next Defence

Next Defence can help public sector teams exercise patch and exposure decisions while maintaining approved delivery of citizen services.

Explore Managed Security Protection ↗

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].