A utility plans to add a managed monitoring service for sites that already have local operators and different communications arrangements. The provider can offer central alert handling and automated enrichment. The utility needs to decide which evidence can be shared, which alerts should reach a site and who has authority to act. A staged rollout lets the service improve visibility while keeping operating decisions with the people responsible for the essential work. The first test should show that one real workflow can be protected and maintained under ordinary and degraded conditions.
Start with a decision the operator needs to make
Choose a representative service, such as receiving a remote monitoring report or approving a supplier support window. Ask the site owner what the operator must know before changing access or pausing work. Identify which records the local team holds, what the central service can observe and which evidence the provider needs. A central alert can identify an event while the site must determine whether the associated work is authorised. Give each organisation a named role and set a route for urgent contact outside ordinary hours.
Write down the operating constraints. Identify the effects of delayed evidence, loss of communications or an unavailable provider. Decide which local work can continue and which action requires a separate operating approval. ASD's principles of OT cyber security emphasise safety and knowledge of the business context. NIST's OT security guidance also addresses reliability and performance. Apply those principles to the monitoring and response arrangement. A successful service should help the site make a decision and should fit the authorised way it operates.
Phase one establishes a baseline and limits evidence collection
Select a small set of authorised event sources and one shift or site. Identify the expected records, collection timing, data owner and current gaps. Agree which information can be sent to the managed provider and what should remain local. Record how events are protected, retained and retrieved. Use common site and service references so analysts can relate a technical observation to the work it affects. ASD and partners' event logging guidance covers collection, protection and correlation across environments. Start with the records needed for the decision rather than gathering unrelated operational information.
Use an approved synthetic event to verify that the right record reaches the service. Ask the analyst to identify the site, affected service, source and time. Give the operator a chance to compare it with an ordinary approval or local record. Document what the provider can establish and what remains with the site. Include a delayed source and observe how the analyst distinguishes loss of monitoring from loss of the underlying service. Assign a named owner for collection and one for verifying service context. Keep the ordinary response process available while the new evidence is being checked.
Phase two adds controlled triage and shift handovers
Give the provider an agreed set of initial use cases and expected communications. For each, state what the alert should describe, which facts are uncertain and who can choose the next action. Use a synthetic event involving an approved supplier session. Ask the provider to send an update identifying the relevant service, expected approval and observation. Have the site owner determine whether the session can continue. Verify whether the message arrives in time and whether the operator can find the evidence without contacting the team that designed the pilot.
Test a communications interruption. Ask the central analyst to identify the last verified event and use an independently established route to reach the site. Have the duty operator explain which work can continue locally and what action requires another decision. Write the result with the operating state and next review time. Give it to the next shift without an oral explanation. If the record depends on an unavailable provider portal, agree how the operator can obtain the minimum evidence through another approved route. Measure whether the service improved the decision rather than counting only how many alerts it acknowledged.
Phase three introduces automation where the result is reversible
Start automation with activities such as adding a known service identifier, finding the approved owner or preparing a draft case for review. Establish which records can be used and which authorities remain outside the tool. If the provider proposes AI-assisted triage, give the information owner a way to verify permitted data and retention. Use fictional records to check that a suggested conclusion identifies its evidence and that a reviewer can correct it. ASD and partners' secure AI development guidance offers a basis for discussing design, deployment and operation. Ask for evidence about the actual configuration and service.
Require a separate decision before allowing an automated capability to affect access or operating work. Identify the exact action, scope, prerequisites and authorised owner. Test it in an approved representative environment and verify a permitted case, a denied case and the ability to stop the change. A utility may choose to keep a human decision for actions that could interrupt a site or affect essential services. Record who can change the automation rule and what observation will show that it remains within the approved boundary after a provider update.
Keep the fallback observable
Plan how the site and provider will operate if monitoring or triage is unavailable. Identify which locally held evidence the operator can use, how an incident can be raised independently and who can accept a temporary limitation. Ask the provider how it will explain a collection delay, change in scope or unverified result. Give the operating owner authority to continue approved work under its established procedures. Document how the records will be reconciled when communications resume and verify that temporary access or procedures are withdrawn.
Use a short exercise with the provider, central team and a new duty operator. Give them a reported access concern, one missing source and an approved task that should remain available. Observe whether the correct owner can decide, whether the new state can be verified and whether the handover explains what remains open. If the provider cannot reach the site or obtain the expected evidence, keep the scope limited while the responsible owner addresses the issue. Repeat the acceptance check under another shift or supplier condition before widening the programme.
When central monitoring and the control room disagree
Take a fictional loss-of-communications alarm from a water treatment site. The remote monitoring provider sees the event as cleared after its collection agent reconnects, but the local operator still has an unresolved indication on the authorised site console. The escalation should not close because a central dashboard is green. Record which site-specific signal must be checked and who is permitted to interpret it. Ask the provider to give the operator an event reference, timestamp quality and any missing interval so the site can reconcile its log. Exercise the opposite condition as well: the site reports a safe normal state while the provider sees delayed events. Define who resolves the disagreement, whether any operational instruction is warranted, and how the decision is handed to the next shift.
Expand when the service can demonstrate the next decision
Report the evidence gathered, the conditions tested and the operating result. Useful measures include time to the accountable owner, time to verified action, coverage of in-scope evidence sources and availability of the approved fallback. Explain which measurements depend on a site, provider or shift. Give unresolved conditions named owners and a date for retest. Choose the next site because it exercises a meaningful difference such as a different communications window or support provider. Reuse the evidence fields and approval process while retesting the parts that change. Managed security operations should make essential work easier to protect and give operators clear evidence for decisions they retain.
At the first post-pilot review, ask another duty owner to explain what the provider can observe, when the site must approve a change and how the fallback is verified. Use the answer to decide whether another source or site is ready to join.
A second operator should be able to locate the pilot record, identify the person with operating authority and repeat the evidence check during a routine handover.
Sources and further reading
- ASD and partners, Principles of Operational Technology Cyber Security
- NIST Guide to Operational Technology Security, SP 800-82 Rev. 3
- ASD and partners, Best Practices for Event Logging and Threat Detection
- ASD and partners, Guidelines for Secure AI System Development
Strengthen your security with Next Defence
Next Defence can help utilities design and verify managed security operations around site conditions, supplier evidence and essential work.