Skip to main content
Next Defence - Next-Gen AI Cyber Security Firm
Australia & New Zealand[email protected](02) 9064 2614
INSIGHT

Security Monitoring for Utilities That Must Stay Online

Design security operations around the utility duty roster, service dependencies and the authority to contain suspicious identity activity.

A utility analyst receives an alert about unusual activity in a cloud administrator's account while field crews are responding to a service interruption. The account has access to the platform used to coordinate field work. Disabling it may be appropriate, but the analyst needs to understand what the account is doing, who will carry the work and which access can be suspended independently. Managed security operations should prepare the utility for this kind of decision. It takes more than forwarding an alert to a control room and waiting for the duty controller to interpret it.

A workable model starts with the service the utility needs to deliver. The cyber team needs a route to the person who understands immediate operational consequences. The control room needs a short description of what has changed, what action is proposed and when a decision is required. Give each side enough information to act and agree on the record both can use when the shift changes.

Establish the operational boundaries

Map two or three essential services before designing monitoring coverage. For a water utility, the map might include service restoration, communications with field crews and remote support for key installations. Document the systems that help deliver each service, their identity platforms, the vendors with support access and the teams responsible after hours. Include systems that merely provide visibility. Losing a read-only view can still remove the evidence a controller needs to coordinate safe work.

Differentiate enterprise identity systems from the engineering and control environments that consume their services. Staff may use a cloud identity for field scheduling, while operational access relies on separately managed accounts. Record any dependencies between these environments and who has verified them. NIST's operational technology security guide treats safety, availability and reliability as explicit considerations. This matters when a monitoring provider suggests an action designed for a corporate endpoint. A control-room workstation, safety system or site gateway may require a different procedure and authority.

Agree who can make the decision at each boundary. A managed provider might suspend a test-approved corporate identity under a standing instruction, while a designated utility manager approves a change affecting field dispatch. Changes to critical plant access should follow the utility’s operating arrangements. Put the contact chain where analysts can find it during an outage and check it against actual duty rosters. Avoid designing the process around one engineer who happens to know every system.

Collect enough evidence to support a decision

Start with identity events, administrative changes and audit records at the systems that connect corporate and operational work. Select sources that can answer specific questions. Was access approved through the normal channel? Did the account obtain a new role? Which applications recorded activity during the relevant period? Can the utility confirm whether a support connection was opened and by whom? Use available read-only exports or established collection points where these satisfy the requirement. Any new collection affecting an operational environment should be planned and approved with the responsible team.

Set expectations for timing, time zones, gaps and retention. For example, a cloud identity alert might arrive quickly, while a third-party platform makes administrative records available through a support request. Document the expected delay and who can make the request at night. Test timestamp interpretation with a known event and confirm that the incident lead can put identity, service and operational records onto one timeline. If a source stops producing useful records, the owner should see that as a coverage issue even when the primary monitoring console still looks healthy.

Review privacy and operational sensitivity before forwarding telemetry. A log may contain employee location, customer information or system details that can be shared only under agreed conditions. Document what fields analysts need, who can view them and where records are stored. Limit access and use approved evidence channels. Give the incident team a way to request additional information when needed and record the purpose for collecting it. This is especially useful when comparing an account action with an activity in the control room.

Design containment around alternative ways to work

In the field coordination example, first identify whether the affected account is used by a person, automation or both. A shared identity can make a small containment decision unexpectedly broad. The platform owner should know which functions depend on it and how to preserve essential work with a separate approved account. Where possible, untangle those dependencies in advance. Use named identities for administrative work and separate workload identities where the platform supports them. Test ordinary access and emergency access independently.

Set out graduated options and their business effects. An analyst might request a targeted session review or an access change affecting one account. A wider administrative freeze may protect critical configurations and delay legitimate work. The on-call decision maker needs to know which option is available, who can implement it and the conditions for changing course. Provide a clear approval route for a control-system action even if the event first appeared in corporate monitoring. A security provider should know when the utility needs to take direct ownership of the response.

Practice the handover with a field supervisor and the duty analyst. Provide a test alert and have each person state the next action they can approve. Then simulate one missing contact and one delayed log source. Record which decisions can still be made and where the team needs a fallback. Compare the proposed timing against the real operating window, including travel to remote sites or the need for a supplier. When the plan depends on a person physically reaching a site, make that dependency visible to the incident lead.

Roll out monitoring in controlled stages

Begin with a business system that affects utility operations but can be exercised safely. Confirm the service owner, collect known test events and establish who receives them. Add one third-party system or gateway only after the first owner can confirm event quality and escalation. Ask the duty controller to review the language used in alerts. A message naming the affected service and proposed action is easier to act on during an outage than a severity label attached to an unfamiliar platform identifier.

At the next review, compare the monitored services against their actual dependencies. Track the time from an observed event to an accountable owner, the number of critical services with a tested containment route and the age of unowned logging gaps. Show separate results for operational systems that require special approval or have limited telemetry. Coverage targets should have a clear denominator and a named source for the inventory. That allows the utility to show what still needs attention when it commissions a site or changes providers.

The goal for the first exercise is straightforward. Produce a meaningful alert from a test identity, reach the responsible duty manager, make an authorised decision and verify that the operating fallback works. Afterwards, have both the control room and the security team confirm the event record and remove temporary access. The exercise will show where the service depends on better evidence, different contract arrangements or faster coordination. Use those results to decide where to expand monitoring next.

Review the exercise with the person who next takes the duty roster. Ask them to find the open decisions and identify which temporary permissions remain active. The record should give a new controller enough context to take responsibility without calling the previous shift back in.

Alert quality must be judged against an operator decision

For a utility monitoring review, create two fictional events: a corporate phishing alert with no OT path, and an unusual historian query associated with an approved maintenance session. Ask the security provider to show the telemetry, context and escalation route used for each. Treat an investigation that merely produces an alert identifier as incomplete if the control-room representative cannot determine whether intervention is required.

An OT engineer should confirm which actions could remove process visibility and which can be simulated or staged. The provider can demonstrate log correlation and communication timing without isolating an operational controller. Measure whether the right duty contacts were reached and whether the original process signals remained visible. That provides a more relevant measure than alert volume alone.

Sources and further reading

Strengthen your security with Next Defence

Next Defence can help utilities define monitoring around essential services, improve visibility across IT and OT boundaries and exercise escalation with operational teams.

Explore Managed Security Operations ↗

LET'S TALK

Let’s talk about your security.

Tell us what you are protecting, where you need greater visibility or what you want to achieve. We will help identify the right next step.

Talk to a Security Specialist

Describe your security requirements. Please do not submit passwords, credentials or confidential incident evidence. This form is not an emergency incident-response channel.

Form powered by HubSpot. Review our Privacy Policy. If the form doesn’t load, email [email protected].