A remote mining site may rely on a supplier identity that can access maintenance instructions or engineering support applications. The exercise places an unexpected contractor login during a shift change, with limited communications available to the site owner.
Prepare a remote-site identity case during a handover
Participants should distinguish evidence that an account was used from any unproven claim that operational equipment was altered. Decisions about disabling access need to be aligned with plant safety and service continuity.
Distinguish contractor maintenance from privilege misuse
- At the first briefing, identify which records and owner can confirm the suspicious login.
- At the second, introduce an unexpected privilege change and require a scoped containment choice.
- At the third, simulate a degraded communications link and test backup contacts.
- At the fourth, seek approved account recovery and vendor reauthorisation.
- Finally, have incident command summarise verified impact and remaining questions.
Keep site containment and evidence on the same timeline
Run the scenario with invented accounts and a whiteboard representation of the site. Evaluate whether a safe access boundary was agreed, the supplier could be reached through a trusted route and evidence was retained for the next shift. Record changes to the contact tree and approvals.
Prepare a remote-site identity case during a handover — test safety
Choose a remote mine with a scheduled maintenance visit, a known contractor identity and a backhaul link that can fail during a shift change. Establish the allowed equipment or application scope and identify who on site can approve emergency restrictions. A harmless simulated login outside the maintenance window should be injected in a test access gateway or tabletop log. The team must not run active authentication attacks against a real plant controller or disable an emergency communication channel.
Distinguish contractor maintenance from privilege misuse — records
Provide the SOC with a time-stamped access event, a separate maintenance ticket and a disputed message from the contractor. Ask investigators to reconcile the three sources, identify what the identity could reach and distinguish confirmed actions from speculation. Where central logging is delayed, preserve locally buffered events and record the clock offsets before constructing a sequence. A successful login need not mean the contractor changed an operational setting; the evidence pack should include both the absence or presence of downstream actions and the period for which visibility is incomplete.
Keep site containment and evidence on the same timeline — sign-off
The site superintendent should decide which remote session can be revoked without removing essential engineering support. The exercise passes only if the team can communicate that decision through the available backup channel, preserve the relevant records and restore authorised contractor access after identity revalidation. A generic incident-close notification will not tell the incoming shift whether a queued maintenance action was completed. Record the final asset state, handover owner and next supported maintenance window.
Set up the remote-site exercise safely
Use a fictional identity and systems that mirror the mine’s real administrative arrangements without accessing production credentials. Prepare a diagram of the remote support gateway, engineering application, corporate identity provider and local communications links. Identify a local site manager, incident commander, identity administrator, engineering lead, security analyst, external supplier contact and a deputy for each critical decision. Agree that all exercise messages are clearly labelled and that no one will revoke actual accounts or block production network paths. Allow ninety minutes plus a separate debrief. State the intended outcomes: verify unusual access, preserve its evidence, decide who may suspend a supplier identity and maintain safe site operations if remote support is interrupted. The exercise should reveal whether the organisation can act within its documented authority even when connectivity or staff availability is limited.
Inject one: a contractor login outside the approved window
At 05:45 local site time, an identity alert shows a contractor account signing into the remote maintenance portal from an unfamiliar network. The access request register contains no matching work order, but the supplier’s roster lists the technician as on call. Provide participants with a synthetic sign-in event containing timestamp, identity, client characteristics and portal name. Ask which facts confirm misuse and which are only anomalies. Participants must find the service owner, check whether the account has standing privileges and establish whether any maintenance is actually scheduled. The facilitator should expect a documented preliminary severity decision and a clear assignment for retrieving gateway and target-system logs. A team should not accuse the supplier of compromise or approve a plant outage solely from the location mismatch, but neither should it ignore the account while seeking perfect certainty.
Inject two: overlapping work and missing communications
At 06:00, the local engineering supervisor advises that a scheduled inspection may require the same supplier later in the shift. The primary satellite link then drops, leaving only voice communications and a limited alternate connection. Security wants to disable the identity globally. Operations asks what will happen if a control-system maintenance issue develops before the supplier can be reached. Participants should identify which access routes are currently active and whether narrower controls can stop further sign-ins without affecting an established safety-critical process. Require a communication plan that names who can call the site, what instruction is safe to deliver verbally and how the decision will be logged if central systems are unreachable. The exercise should assess coordination under reduced visibility rather than rewarding a simplistic “disconnect everything” response.
Inject three: evidence of a new privileged action
At 06:20, the gateway log reveals a successful session to an engineering support host and a recent administrative-group membership change. The supplier denies authorising a role expansion. The facilitator may present a second event showing a legitimate emergency support request from another team, creating conflicting explanations. Ask the analyst to correlate the records and explain what remains unknown. The identity administrator proposes revoking active sessions, rotating the account credentials and examining related service identities; the plant owner must decide whether any of those actions affect operational continuity. Require the team to preserve audit exports, approval records and the identity timeline before destructive administrative changes where doing so is safe. Score the response on evidence quality, authorised containment and operational impact. The goal is to prevent additional privilege use while preserving the ability to reconstruct what occurred.
Inject four: supplier and management escalation
At 06:45, a senior operations executive requests confirmation that the site has not been compromised. The supplier security contact is unavailable, while local staff report delayed access to a routine maintenance record. Participants must deliver an update that separates confirmed facts, suspected exposure, actions taken and the next decision point. They should avoid claiming that no data was accessed merely because no alert fired. Check that the incident commander can initiate the supplier escalation route in the contract and reach an alternate contact. The communications lead should prepare a concise internal message for the shift supervisor and a conditional external notification plan subject to legal and regulatory assessment. This tests whether management receives useful uncertainty rather than a reassuring but unsupported statement.
Preserve evidence across systems and time zones
Prepare an evidence worksheet recording the event source, timestamp with time zone, identity, affected host, collector status, export custodian and relevant integrity information. Compare the cloud identity log with the local gateway record and the engineering application’s audit trail. A delayed network connection may cause events to arrive centrally out of order; participants should distinguish event time from ingestion time. Avoid collecting sensitive engineering drawings or employee information unnecessarily. Set a chain-of-custody approach proportionate to the incident and keep original logs wherever practicable. If a device is too safety-sensitive for intrusive forensic collection, record a supervised alternative and the limitation it leaves. A complete evidence pack should support a defensible access timeline without creating a second operational incident through careless acquisition.
Select containment measures by dependency
Ask the group to create a short containment matrix for a normal contractor account, a highly privileged supplier administrator and a service identity supporting automated maintenance records. For each, list the least-disruptive effective control, approval authority, impact on the site and verification method. Options may include terminating a known session, disabling new authentication, restricting an approved gateway path or rotating a scoped credential. Avoid indiscriminate changes to industrial devices as part of a tabletop. Once a measure is selected, define what log proves it worked and how the team will detect an attacker using a second identity or alternate route. If the required authority is unavailable, follow the documented emergency decision process and record the residual exposure. This turns containment from a product-button demonstration into an accountable operational decision.
Plan safe restoration of contractor access
After the simulated identity is contained, the supplier requests restored access to complete urgent work. Participants must define conditions for re-enablement: confirm the legitimate technician, reapprove the work order, issue a new narrow credential, validate endpoint trust where possible and set a clear expiry. Check whether any privileged changes performed during the suspicious session need review or rollback before reconnecting. A local site supervisor should sign off the operational necessity, and the security team should confirm that monitoring is active on the restored route. Record the method of notifying staff that old credentials must no longer be used. Do not conclude the exercise at the moment of account disablement; secure resumption of maintenance is part of the incident lifecycle and can reveal overlooked dependencies.
Score the decisions and identify follow-up tests
Use a zero-to-three scale for six domains: identification, evidence, authority, containment, communications and restoration. Zero means the required information or owner could not be found; one means a procedure exists but was not executable; two means the team made a workable decision with gaps; three means a traceable decision was demonstrated with required approvals and verification. Require a specific example supporting each score. The debrief should record the most consequential decision delay, the contact or data missing at that point and the business impact of the gap. Convert these into actions with owners, deadlines and a closure test, such as a supervised synthetic sign-in, an after-hours supplier contact check or a review of privileged-role expiry. Avoid a single average score that hides a failure of plant safety authorisation.
Make the rehearsal repeatable at other sites
Package the synthetic events, decision worksheet, approved site-role matrix, scoring rubric and lessons learned so another site can repeat the exercise without copying its particular facts. Change the supplier, communication failure and affected host for the next run to test whether responders understand the underlying procedure. Compare how long it takes to reach an authorised operational decision and whether complete access records are available. Revalidate contact lists after roster or supplier changes. Schedule the next exercise after the most important fixes have been tested, and include one unfamiliar deputy to ensure capability does not depend on a single experienced person. The value is a reliable remote-site response process that works under real operating constraints, not an impressive one-off simulation.
Sources and further reading
- NIST — Computer Security Incident Handling Guide (SP 800-61 Rev. 2)
- NIST — Guide to Computer Security Log Management (SP 800-92)
- CISA — Cross-Sector Cybersecurity Performance Goals
Strengthen your security with Next Defence
Next Defence supports mining, energy & resources organisations with practical assessment, technical implementation and validation through its Incident Response & Cyber Resilience practice.