A power-services contractor works across several regions, supporting engineering workstations, asset-management applications and selected utility control environments. Its staff use one corporate identity, but each contract grants different permissions. A valid login must not become unrestricted access to every site. This zero trust test asks whether the organisation can enforce identity, device, location, job approval and resource boundaries for each connection—and whether a compromised or retired contractor account would be contained.
Define the real trust zones before configuring policies
List the relevant users, devices, applications and site boundaries. A regional engineering portal may be an enterprise IT service, while a jump host provides controlled access toward operational technology. These are different security domains. Identify whether the same contractor is authorised to view asset drawings in one region, submit a maintenance ticket in another and connect to OT engineering tools only at a named site. Avoid describing all of these as a single “VPN user” role.
The utility’s operations owner should classify systems by safety and service importance. An identity team can define sign-in controls but should not approve remote access to plant equipment without the operational authority responsible for that process. Document the use case, approved destination, permitted operations, access window, sponsor, device requirements and logging expectations for each contractor assignment.
Use separate synthetic contractor accounts and test applications. No live PLC access or unapproved network scanning is required. The exercise should prove policy behaviour at safe boundaries, with any later OT validation performed only under site-approved procedures.
Draw an access map that includes indirect paths
For each site, identify the entry point, identity provider, device posture service, broker or jump host, application proxy, administrative account and destination. Note any legacy VPN that still provides subnet-wide reachability, even if new applications use context-aware access. A zero trust branding label on the front door does not remove the exposure of a backdoor maintenance network or shared local administrator account.
Map service-to-service identities too. A remote support platform may maintain an unattended agent, and a monitoring integration may hold an API token with permissions broader than the human technician’s role. Treat these identities as separate access grants with their own owners, permitted actions and revocation procedures.
Ask whether contractors can move between regional environments using inherited groups, replicated directory permissions or universal cloud application roles. A user assigned to one substation should not gain access to another because both sites use the same support portal. Test the actual application and network decisions, not only the naming of groups in a directory.
Prepare representative identities and devices
Create three test principals: a current contractor approved for Site A, a contractor whose Site A work has ended, and an emergency specialist approved for a time-limited Site B task. Include one managed, compliant test laptop and one device that deliberately fails the chosen posture condition. Establish the allowed operations for each principal and whether privileged access requires additional approval and stronger authentication. Keep the accounts synthetic but use the same policy types as the real environment.
Record initial token issuance, group memberships and application assignments. If a policy relies on geographic location or source IP, test that assumption carefully: travel, roaming connections and cloud proxy egress can make IP-based location misleading. A context signal should contribute to the decision, not substitute for a sound resource permission model.
The exercise should have a business sponsor who can approve legitimate work and a separate reviewer who observes failed attempts. An account administrator should not be the sole person declaring that their own configuration is effective.
Test authorised access to a single site
Have the current Site A contractor authenticate on the compliant device through the approved identity flow. Verify that the broker directs them only to the designated application or controlled jump environment. Attempt a harmless operation such as opening a synthetic maintenance ticket or reading a test drawing. Record the session identifier, requested resource, policy decision, assigned role and relevant application audit entry. A network connection alone does not establish whether the intended fine-grained operation was authorised.
Now attempt the same request against Site B using a direct application URL and, where appropriate, a documented API route. The expected result is denial based on missing Site B entitlement. Test a resource identifier belonging to a different site as well; a user-interface menu that hides Site B while accepting a direct object request is not a satisfactory boundary.
For privileged work, verify that an elevation request is attributable and time limited. An approval may be bound to a specific application and service ticket instead of creating a general administrator session. Record when elevation expires and whether the user can continue with ordinary non-privileged duties afterward.
Test device and session context changes
Use the non-compliant test device to attempt the approved Site A connection. Observe whether the identity or access broker blocks the session, limits access or requests remediation according to policy. Check that the decision relies on a trusted device posture signal rather than a client-supplied flag. Document how temporary offline operation works; an OT maintenance engineer may occasionally work in areas with unreliable connectivity, but a general exemption should not quietly become permanent.
Next create a valid session on a compliant device, then simulate a changed risk state through the test environment. Determine whether access is reevaluated during the session, on token refresh or only at the next sign-in. An “always verify” principle does not mean every request necessarily triggers full interactive MFA, but high-risk actions should have appropriate real-time authorisation and short exposure windows.
If a session continues after the device becomes non-compliant, document the product limitation and compensating controls. Do not claim continuous enforcement based only on a sign-in policy screenshot.
Verify contract expiry and revocation
The test contractor’s job order ends at a defined time. Revoke the Site A assignment through the actual lifecycle path, then attempt to reuse an existing session and any approved remote-support channel. The expectation is that access ends within the organisation’s defined revocation objective. Measure the effective delay and whether the denial occurs at the identity layer, application, broker or network gateway.
A manager’s removal of a project tag is not necessarily enough if a separate local account, unattended agent or credential remains active. Review local authorisations, emergency accounts and service identities tied to the contractor. Confirm that a departed supplier cannot use previously created tunnels or cached privileged credentials to continue work. A service contract can end while a technical integration still runs; assign each identity type to an accountable owner.
Protect existing operations while removing access. A blanket disable command might also terminate a safety-related support service still required under another approved agreement. Use narrowly targeted entitlement cleanup supported by a tested emergency procedure where the situation demands it.
Exercise a cross-region emergency without bypassing controls
The facilitator announces a simulated fault at Site B. The approved specialist is travelling, and the usual site sponsor is temporarily unavailable. Ask the team to follow its emergency access process. Who can establish the operational need? What record is created? Can access be granted to the particular site and function for a bounded period? Who monitors the session, and who removes permission afterward?
A break-glass path should be designed and rehearsed before a fault. It may use stronger identity proofing, an approved alternate authoriser, a monitored jump host and short-lived elevation. Do not make an emergency the reason to issue a permanent multi-region admin group. Equally, do not build a policy that prevents safety-critical support when the normal manager is asleep; operational risk has to be treated explicitly.
The simulated specialist should be able to demonstrate an approved harmless task only at Site B. Repeat the Site A and unrelated Site C negative tests. The access decision should follow the job scope, not the urgency label alone.
Include OT safety and availability safeguards
Security teams should distinguish enterprise access policy testing from testing of an actual industrial control process. For OT, coordinate every planned change with engineers who understand process reliability, vendor support dependencies and safe operating limits. Passive monitoring, remote session recording or a new broker can affect fragile systems or response time; verify compatibility in a non-production or approved test setting before relying on it.
Avoid exposing control protocols directly through general-purpose remote access. A controlled intermediary can narrow reachable assets and record operator activity, but its own resilience matters. Ask what happens if the access broker is unavailable during an urgent maintenance window: which approved local procedures keep the plant safe, and how are emergency actions audited afterward? The answer depends on site engineering, not on a universal identity-policy template.
Use the exercise to identify broad network routes inherited from older suppliers. Even if new users are authenticated through a strong portal, a separate legacy VPN may permit direct connections that bypass the intended resource-level checks. The final map must include these alternate paths.
Create a decision and evidence matrix
For each test record the actor, device, approved job, destination, requested operation, policy version, expected result, observed result and log reference. Include the four combinations that reveal policy gaps: approved identity/approved site, approved identity/unapproved site, expired identity/former site and emergency identity/approved limited task. Add the device-posture negative case and a direct API or resource-ID attempt where the system supports it.
Grade outcomes as verified pass, verified fail, not demonstrated or approved exception. A sign-in denied at the portal may show one effective control, but it does not prove that a pre-existing service token or unattended remote agent is disabled. Record those as separate tests. If a vendor cannot provide session revocation or activity logs, the business owner needs to accept or remediate that limitation explicitly.
An independent reviewer should be able to trace a requested operation to the policy decision and the application outcome. A screenshot of an access group is contextual evidence, not the primary proof. Sensitive engineering documents and plant details should not be copied into general audit tickets.
Set minimum acceptance and review triggers
Accept the design only when the approved contractor can complete the bounded task, another site remains inaccessible, a non-compliant device is handled according to policy, permissions expire as intended and emergency elevation is both usable and attributable. Verify that the actual application enforces the decision after authentication and that logs can support an investigation without exposing operational secrets.
Assign any failed route to the right owner: identity architecture for token lifetime or claims, application engineering for object authorisation, network engineering for legacy paths, OT operations for safe remote access, and procurement for supplier termination obligations. Re-test after mergers, contract renewals, regional access redesigns, identity-provider changes and deployment of new remote maintenance tools.
The outcome is not a claim that every connection is risk-free. It is a measured demonstration that a valid login does not become permission to roam across utilities, and that access changes with the authorised job, device and operational context.
Sources and further reading
- NIST, SP 800-207, Zero Trust Architecture (2020)
- ASD, Principles of operational technology cyber security (2024)
How Next Defence can help
Next Defence can assess utility identity decisions across field devices, remote vendors and central applications, using both permitted and prohibited journeys. Start with an agreed scope for Cloud, Identity & Data Security and an operations-approved test boundary.